This is a prospective multicenter study whose purpose is to establish the safety and effectiveness of the Edwards SAPIEN 3 and SAPIEN 3 Ultra valves with Commander delivery system in patients with severe symptomatic calcific mitral valve disease with severe mitral annular calcification (which is a progressive loss of function of the mitral valve due to…
This is a prospective, single-center, single-blind, two-arm, 1:1 randomized clinical trial. Patients who have undergone successful elective PCI will be screened with a lipid profile and eligible patients will be enrolled. Non-eligible patients will be enrolled in a registry. Randomization will be stratified by baseline LDL-C level and current statin therapy…
This is a Prospective, multicenter, randomized, parallel-controlled, open-label two-arm trial with an adaptive design that will randomize about 1252 subjects at approximately 120 US and international centers. The study is looking to see if a device called the Impella device will improve the way the heart works as well as if health is improved as compared to…
This is a randomized controlled trial (RCT) that will compare the clinical outcome of MitraClip device versus surgical repair in patients with severe primary MR who are at moderate surgical risk and whose mitral valve has been determined to be suitable for correction by MV repair surgery by the cardiac surgeon on the local site heart team. In this trial,…
The study is designed to compare the safety and effectiveness of the PASCAL System to the MitraClip System for reduction of degenerative mitral regurgitation.
The primary objective is to demonstrate that physiologically-guided stenting using the Philips SyncVision iFR co-registration is superior with respect to clinical outcomes compared to PCI guided by angiography alone. Secondary objectives include: To evaluate the cost-effectiveness of physiology guidance with SyncVision compared to a standard of care PCI…
Have you ever received treatment in an ICU, do you have a smartphone (iPhone or Android), and are you at least 18 years old? If you answered yes to the above, you may be eligible for the Messy Memories Study. All study activities are completed from the comfort of home, and participants are asked to: 1. use a smartphone to revisit memories of the ICU, and 2…
This study is trying to determine if using a Dynamic Coronary Roadmap (which is a software used along with an x-ray imaging system) reduces the total iodine contrast volume per Percutaneous Coronary Intervention (PCI) procedure compared to procedures performed without Dynamic Coronary Roadmap. This X-ray system provides imaging support while directing the…
This study is designed to look at the safety and performance of The Intrepid TMVR System using transfemoral transseptal access (TF). TF is a procedure that requires access to the femoral vein by an incision in the lower limb between the knee and the hip. The study population is for patients with severe, symptomatic mitral regurgitation (MR), a condition…
The Millipede Feasibility Study is a prospective, open-label, single-arm study to assess the safety and feasibility of the Millipede Transcatheter Annuloplasty Ring System in subjects with functional mitral regurgitation. The Millipede Annuloplasty Ring System is a novel transcatheter, fully adjustable, complete annuloplasty repair device for the treatment…
The purpose of this study is to evaluate a new device to treat patients who may benefit from the repair of their mitral heart valve due to mitral regurgitation. The device is called the Edwards Cardioband System (Edwards Cardioband System or the device). The device is investigational in the United States but has been approved in Europe. This clinical study…
The Saranas Early Bird Bleed The Saranas study uses a device is called the Early Bird Bleed Monitoring System (EBBMS) and it is intended to provide physicians with an early indication of a potential internal bleeding complication due to vessel injury that may occur during the procedure before any symptoms present.
This study has been designed to treat patient with coronary artery disease and demonstrate the superiority of the OCT device used to select and guide the stenting procedure when collecting images and flow measures inside the blocked artery.
This is a research study designed to look at the safety and effectiveness of the TriGUARD 3 cerebral embolic protection device in patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of the study is to assess whether the TriGUARD 3 can prevent death, stroke, more subtle signs of brain injury, and/or silent brain injury as measured…
This trial is a non-randomized, prospective, multi-center early feasibility study to evaluate the safety and performance of the AccuCinch system in patients with Heart Failure and Reduced Ejection Fraction HFrEF
The purpose of this study is to collect data for evaluating VFR (Virtual Flow Reserve) in comparison with standard FFR (Fractional Flow Reserve) when patients undergo a percutaneous coronary intervention (PCI) to treat blockage or narrowing in the heart artery or arteries.
A study evaluating the placement of any guidewire beyond complex narrowed arteries that are relatively common in patients undergoing ballon angioplasty (a procedure where a balloon is used to stretch open narrowed arteries). At least one Teleflex guidewire and at least one Turnpike catheter is used. The guidewires and catheters that are being studied are…